Items |
Characteristics |
Rated capacitance range CR |
68 … 150.000 µF |
Capacitance tolerance |
± 20% |
Rated voltage range UR |
16 … 450 V |
Surge voltage US |
UR ≤ 315 V: US = 1,15 UR
UR > 315 V: US = 1,10 UR |
Max. reverse voltage |
2 V |
Category temperature range |
- 40°C ... + 105°C |
Leakage current IL after 5 min @ UR |
≤ 0,008 * CR [µF] * UR [V] + 6 µA [µA] |
Useful life |
5000 h@ 105 °C ; UR ; IR~ |
Requirements
Δ C/C ≤ 30 % of initial value
ESR ≤ 300 % of specified limit
IL ≤ specified limit |
Endurance test |
2000 h @ 105 °C , UR |
Requirements
Δ C/C ≤ 20 % of initial value
ESR ≤ 130 % of specified limit
IL ≤ specified limit |
Climatic category IEC 60068 |
40/105/56 |
Voltage proof of the external insulation |
³ 2500 V AC |
Sectional specification |
IEC 60384-4 |