Items |
Characteristics |
Rated capacitance range CR |
390 … 3.300.000 µF |
Capacitance tolerance |
± 20% |
Rated voltage range UR |
16 … 450 V |
Surge voltage US |
UR ≤ 315 V: US = 1,15 UR
UR > 315 V: US = 1,10 UR |
Max. reverse voltage/ ESL |
2 V / 20 nH |
Category temperature range |
- 40°C ... + 85°C |
Leakage current IL after 5 min @ UR |
≤ 0,008 * CR [µF] * UR [V] + 6 µA [µA] |
Useful life |
12000 h @ 85 °C ; UR ; IR~ |
Requirements
Δ C/C ≤ 30 % of initial value
ESR ≤ 300 % of specified limit
IL ≤ specified limit |
Endurance test |
4000 h @ 85 °C , UR |
Requirements
Δ C/C ≤ 20 % of initial value
ESR ≤ 130 % of specified limit
IL ≤ specified limit |
Climatic category IEC 60068 |
40/085/56 |
Voltage proof of the external insulation |
³ 2500 V AC |
Sectional specification |
IEC 60384-4 |