Items |
Characteristics |
|
Rated capacitance range CR |
10 … 82.000 µF |
|
Capacitance tolerance |
± 20% |
|
Rated voltage range UR |
16 … 450 V |
|
Surge voltage US |
UR ≤ 315 V: US = 1,15 UR
UR > 315 V: US = 1,10 UR |
|
Max. reverse voltage |
2 V |
|
Category temperature range |
- 40°C ... + 105 °C |
|
Leakage current IL after 5 min @ UR |
≤ 0,008 * CR [µF] * UR [V] + 6 µA [µA] |
|
Useful life |
3000 h@ 105 °C ; UR ; IR~ |
Requirements
Δ C/C ≤ 30 %of initial value
ESR ≤ 300 % of specified limit
IL ≤ specified limit |
|
Endurance test |
2000 h @ 105 °C , UR |
Requirements
Δ C/C ≤ 20 % of initial value
ESR ≤ 130 % of specified limit
IL ≤ specified limit |
|
Climatic category IEC 60068 |
40/105/56 |
|
Voltage proof of the external insulation |
D ≤ 25 mm: ≥ 1000 V AC
D > 25 mm: ≥ 2500 V AC |
|
Sectional specification |
IEC 60384-4 |
|
Øleads |
Up to 25 mm Ø : 0,8 mm ;
more than 25 mm Ø : 1,0 mm |